SDIF-2 or Slave Clock In (BNC): This connector can receive either an SDIF or Slave
Clock Sync signal (the FC726 automatically detects the signal type). An SDIF device must
send a Word Sync signal to this connector to interface properly. Slave Clock is a sync signal
(commonly implemented in Pro Tools systems and referred to as a super-clock) that runs
at 256 times the sample rate. Cable not provided.
MADI B In 1 / MADI B Out 1 (two BNC): Connect these MADI Ports to the DF64 or
optional SH612 Studio Hub (cable provided).
Format B AES Sync In (female XLR): Connect this port to a digital sync reference.
Format B AES Sync Thru (male XLR): This signal is active regardless of selected sync
source.
Format B Word In (BNC): Connect this port to a digital sync reference.
Format B Word Out (BNC): This signal is active regardless of selected sync source.